0% Complete
صفحه اصلی
/
ششمین کنفرانس بین المللی میکروالکترونیک ایران
High Figure of Merit Metasurface Biosensor at Optical Telecommunication Band
نویسندگان :
Hemin Ebrahimi
1
Keyhan Hosseini
2
Mohammad Razaghi
3
1- دانشگاه کردستان
2- دانشگاه کردستان
3- دانشگاه کردستان
کلمات کلیدی :
Biosensor،figure of merit،hexagonal ring،metasurface،ZrN
چکیده :
A metasurface biosensor is designed at the optical telecommunications band to detect cancerous cells. The unit cell is a hexagonal ring hole etched on a sliver thin film deposited on a ZrN layer backed by another Ag layer and a SiO2 glass substrate. Four veins are introduced to the hexagonal ring to decrease the 3-dB bandwidth of the dips appeared in the reflectance spectrum of the sensor. The resonance frequencies of the sensor loaded with the cultured and cancerous analytes are 1.445, 1.486, 1.489, and 1.493 μm. The sensitivity and figure of merit (FoM) of the proposed biosensor are observed to be 986 (nm/RIU), and 417, respectively. Such an extremely high FoM finds applications in distinguishing between cancerous cells with very low refractive index contrasts. Further detailed results are presented at the conference.
لیست مقالات
لیست مقالات بایگانی شده
Three-Phase Bidirectional Integrated Meter Using Hall Effect Sensor in 0.5um CMOS Process
Shayan Anzali - Morteza Mousazadeh - Khayrollah Hadidi
An Ultra-Low-Voltage, High-Voltage Gain, Bulk-Driven CMOS Operational Amplifier
Ali Nejati - Mohammad Hossein Maghami
A Curvature Compensated CMOS Bandgap Voltage Reference With 6.8 ppm/°C Temperature Coefficient and Low Quiescent Current
Elaheh Pakravan - Mortaza Mojarad - Behboud Mashoufi
تشخیص خودکار نقص های برد مدار چاپی با بهره گیری از مدل یادگیری عمیق یولوv5
سید حامی حسینی - سمیرا مودتی
Quantitative study of Temperature-Dependent BandGap Energy and Its Influence on Threshold Potential Characteristics of MOS Devices
Hanieh Khakvatan - Sarang Kazeminia
Optimizing High Dynamic Range Current Measurement Circuit for IoT Applications
Yas Hosseini Tehrani - ُSeyed Mojtaba Atarodi
Comparison between Hardware/Software Co-design of RiscV Vector and Scalar Implementation of Deep Neural Networks
Seyed Kian Mousavikia - Morteza Mousazadeh
Broadened graded asymmetric waveguide structure for low divergence 915nm diode laser
Seyed Peyman Abbasi - Arash Hodaei
یک مبدل آنالوگ به دیجیتال مبتنی بر مدولاتور سیگما دلتا برای کاربردهای مهندسی - پزشکی با ENOB = 13. 2 bits ، پهنای باند 10 kHz و توان مصرفی 16.9 µ W
علی صداقت - حسین پاک نیت - نوید یثربی
Numerical analysis of studying the importance of choosing the right image reconstruction algorithms in tomography’s accuracy and processing time
Maryam Ahangar Darband - Esmaeil Najafiaghdam
بیشتر
ثمین همایش، سامانه مدیریت کنفرانس ها و جشنواره ها - نگارش 44.5.0