0% Complete
صفحه اصلی
/
پنجمین کنفرانس بین المللی میکروالکترونیک ایران
Numerical analysis of studying the importance of choosing the right image reconstruction algorithms in tomography’s accuracy and processing time
نویسندگان :
Maryam Ahangar Darband
1
Esmaeil Najafiaghdam
2
1- دانشگاه صنعتی سهند
2- دانشگاه صنعتی سهند تبریز
کلمات کلیدی :
Tomography،Image Reconstruction،Photoacoustic Tomography (PAT)،Breast Cancer
چکیده :
Tomography plays an important role in imaging, especially medical imaging. One of the most important parts affecting the speed and accuracy of tomography is choosing the right image reconstruction algorithm. Photoacoustic tomography has grown significantly in recent years due to its non-invasiveness and low risk and at the same time high optical contrast with good ultrasound resolution. In this presentation, by choosing photoacoustic tomography in diagnosing breast tumors, we studied the accuracy and speed of two image reconstruction algorithms suitable for the proposed geometry. According to the simulation results of the spatial phase-controlled algorithm and algebraic algorithm at COMSOL, the spatial phase-controlled algorithm is 24.48 seconds faster than the algebraic algorithm and has a better resolution compared to the algebraic algorithm. According to these results, the appropriate choice of the image reconstruction algorithm based on the geometry and type of tomography plays a significant role in the resolution and speed of tomography.
لیست مقالات
لیست مقالات بایگانی شده
A 2x1 Bit Multiplier Based on Vibrating Microelectromechanical Resonators
ALI DELVAR - Farshad Babazadeh
A 10-bit, 110-MS/s Synchronous SAR ADC Using a Split‑DAC Architecture with the new comparator
Sajjad Ali Abbasi Yaghmourali - Morteza Mousazadeh
A -73.3 dB-THD ±285 mV DC Offset Rejection Analog Front-End with Novel Chopper Spike Filter for Wireless Wearable ECG Sensors
Mahsa Sadeghi - Mohammad Yavari
A Nonlinear, Low-Power, VCO-Based ADC for Neural Recording Applications
Reza Shokri - Yarallah Koolivand - Omid Shoaei - Orazio Aiello - Daniele Caviglia
جاذب کامل مبتنی بر گرافن با حساسیت بالا برای کاربردهای تشخیص سرطان
علیرضا پیله رودی - جواد جاویدان - حمید حیدرزاده
A Curvature Compensated CMOS Bandgap Voltage Reference With 6.8 ppm/°C Temperature Coefficient and Low Quiescent Current
Elaheh Pakravan - Mortaza Mojarad - Behboud Mashoufi
Beyond Silicon: A Roadmap for Graphene-Based Field-Effect Transistors in RF Amplifiers, Biosensing, and Integrated Flexible Electronics
Sina Pourhajiagha Golestani - Esmaeil Najafiaghdam - Kiyumars Jalili
Design and Implementation of novel Microgrid Inverter
Amirhasan Sobhi - Alireza Zabihi - Sina Chartabi - Mina Salim
Characteristics of Electrophoretic Graphene-oxide (GO) Film on Permalloy (Ni-Fe) Thin Film Sputtered on Copper Substrate
Ali Rezaei
Numerical Assessment of Serpentine Microchip Capillary Electrophoresis Channels Over Straight Channels
Ehsan Nikkhah - Hadi Veladi - Abolghasem Jouyban
بیشتر
ثمین همایش، سامانه مدیریت کنفرانس ها و جشنواره ها - نگارش 44.5.0